Digital I/O - DI / DO / Relay / Counter

This type of module is primarily used for industrial control, monitoring and control. Is very hardy and suitable for external applications where they can be assembled with other type of modules in order to solve a complex task. Is widely used for building automation, factory automation, production machines, energy management etc. Contact DANBIT if you have special wishes and requirements to be met.

Digital I/O - DI / DO / Relay / Counter

Active filters

lens In stock

4 opto-isolated digital inputs and 8 digital outputs, open collector, RS485

kr1,277.00

8 digital outputs and 4 digital inputs
Open Collector Output
Photocouple Isolation
Digital input channels can be used as 16-bit counters
Configurable Power-on Value settings
Configurable settings for sure value
3750 Vrms insulation voltage
Dual Watchdog
Wide operating temperature range: -25 to + 75 ° C

Reference: M485-DIO4-I
lens In stock

Network Module with Digital I / O Korenix Jeti / O 6550

kr1,394.00

Network module with digital I / O Korenix JETI / O 6550
Channels: 14/8
Digital inputs: 14 pcs., Logic 0: 0 - 4 V, Logic 1: 5 - 30V
Digital outputs: & nbsp; 8 pcs. Open collector, 5 - 40 V 250mA
Isolation: Optical 2500 VRMS for analog and digital inputs and outputs for the power supply
Magnetic 1500 V from the network interface for the power supply
10/100 Mbit m / RJ45 their connector
Operating temperature: - 25 ° C - 70 ° C
Supports Modbus / TCP, OPC server, SNMP. Software included for configuration
For DIN rail mounting
Supply: 10 - 30 VDC via terminal block, Max 1.92 W

Reference: ETHIO14D8D-K
lens In stock

12 x Digital inputs and 6 x Digital outputs. 1 x RJ45 Ethernet. Modbus/TCP / Modbus/UDP. Pair-compound, 10 - 30VDC

kr1,858.00

Built-in Web server
Web HMI
Support for both Modbus TCP and Modbus UDP protocols
Communications Security
1 x RJ45 Ethernet port
Double watchdog
Operating temperature range: -25 to +75°C
I/O pair connection, the input is mirrored in the other's output
Built-in I/O
12 x Digital input: Wet / Dry, 0 - + 50VDC
All entries are 32-bit counter 500Hz
6 x digital output: Open Collector 0 - + 30VDC / 100mA
Supply voltage: 10 - 30VDC

Reference: ETHIO12I6O-I
lens In stock

6 x Digital input, 6 x Relay output via Ethernet for industrial control applications. 1 x RJ45 PoE

kr2,013.00

6 x Digital Inputs - Wet (active at DC in)
6 x Power relay outputs - 24VDC / 250VAC / 5A
Protocol: Modbus TCP / UDP
1 x RJ45 Ethernet interface with PoE in
I / O Pair-function - the input is mirrored to the second output
Digital inputs with counter - max 500Hz
the minimum pulse width: 1 ms
Screw terminal
Supply voltage: PoE or 10 - 30VDC / 3watt

Reference: ETHIO6I6PR-P-I
lens In stock

8 x Digital inputs Wet 0 - + 50VDC 500Hz, 8 x Digital output (OC) + 40VDC 650mA, 2 x RJ45, Modbus TCP/UDP, 12 - 48VDC

kr2,300.00

Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair connection - the input is mirrored in the other's output
8 x Digital input (count): 0 - + 50VDC (500Hz)
8 x Digital Outputs: Open Collector 0 - + 40VDC / 650mA per output
2 x RJ45 Ethernet - daisy chain
Supply voltage: 12 - 48VDC / 4Watt

Reference: ETHIO8I8O-2I
lens In stock

Zigbee Router - Wireless IO module. RS232 and RS485 to Zigbee converter. 2.4GHz ISM frequency band

kr1,900.00

ISM 2.4 GHz Operating Frequency
Fully Compliant with 2.4 G (IEEE802.15.4/ ZigBee Specifications)
Fully Compliant with ZigBee Pro (ZigBee 2007)
Wireless Transmission Range up to 700 m (Default)
Adjustable RF Transmission Output Power
Supports AES-128 Encryption for the Wireless Communication
GUI Configuration Software (Windows Version)
RS-232/RS-485 Interface Supported
Source Identification for the non-address Device Data Transmission
Supports Broadcast Transmission for the Redundancy Transmission Path
Supports Unicast Transmission to Reduce Network Loading
Supports Topology Utility for Network Monitoring and Improvement
DIN-Rail Mountable

Reference: ZIG-SL-I
lens In stock

Ethernet Module with Modbus TCP/IP. 2 x digital input, 2 x power relay output, I/O Pair connection, 12 - 48VDC

kr972.00

Ethernet I/O module Modbus/TCP / UDP slave
1 x RJ45 Ethernet
Redundant Power Supply
Protocol: TCP, UDP, HTTP, DHCP, BOOTP and TFTP
Web configuration and firmware update via Ethernet
2 x digital input (Wet - volts supplied)
2 x Relay, COM, NO - 250VAC 5A, 30VDC 5A
Avoid inductive load to relay contacts
With locked DI and 32-bit 3.5kHz counter
With I/O pair - input is mirrored in the other's output
Dual-watchdog with Power-on-safe value
Supply voltage: 12 - 48VDC, 1.7 Watt
Dimensions: 98 x 52 x 27 mm
Operating temperature: -25 - +75°C

Reference: ETH-MOD2I2R-I
lens In stock

8 x DI Wet/Dry 0 - +50VDC 500Hz, 8 x DO +40VDC 650mA, 2 x RJ45, Modbus TCP/UDP, PoE and 12 - 48VDC

kr3,077.00

Built-in Web server
Web HMI
Modbus TCP and Modbus UDP protocols
Good communication security
Dual Watchdog
Operating temperature range: -25 ~ + 75 ° C
I/O Pair - Input Mirrors at the second's output
8 x Digital input (counter): 0 - + 50VDC (500Hz) - Wet / Dry
8 x Digital output: Open Collector 0 - + 40VDC / 650MA per Ch 
2 x RJ45 Ethernet - Daisy Chain
Supply voltage: POE or 12 - 48VDC / 4Watt

Reference: ETHIO8I8O-P2I+
lens In stock

Web-enabled analog input module. 8 x analog in, volt, 4-20mA, Sample Rate 25Hz with log, 1 x RJ45, Modbus/TCP, PoE, 9 - 28VDC

kr5,743.00

8 x analog inputs - Sample Rate 25 times per second
8 x input - Single ended: ± 1.28V, ± 2.56V, ± 5,12V, ± 10,24V
input 1 - 4 Can be 4-20mA
Web server for configuration and remote monitoring
Permissions: Administrator, Manager, User
Tasks
50 schedule planned
50 Conditional
20 overroubed
Email Alarms by Defined Terms
Supports Encrypted Email Servers, such as Gmail
RTC with NTP server synchronization
No software Required
Basic Script Support for Advanced Flexibility
Logging - Graph Presentation
static or DHCP IP Address Configuration
Modbus, SNMP, Remote Service, IP Filtering
On-site update
Supply voltage: PoE or 9 - 28VDC

Reference: X-418-E