Løsninger

Train computers and EN 50155

1 min. læsning

A train stays in service for 30 years. The computer on board has to last just as long. EN 50155 is the standard that decides whether equipment may be installed in rolling stock. It covers temperature, power, vibration and fire safety.

30 yearsexpected service life
-40 to +85degrees in class TX
10 mspower loss without restart

The temperature class drives the components

EN 50155 sorts equipment into temperature classes. The class follows from where the unit sits in the train. A cabinet in a heated carriage is easier than an underfloor position.

EN 50155 temperature classes T1, T2, T3 and TXClass TX covers the full range from -40 to +85 degrees. That requires extended temperature memory and storage.

Power is the hard part

ConditionTypical requirementWhat it means for the hardware
Nominal voltage24, 36, 48, 72 or 110 V DCWide input range, not a fixed supply
Variation0.7 to 1.25 times nominalMust keep running on a low battery
Short interruption10 ms or 30 msNeeds buffering so the system does not reboot
TransientsProtection requiredFiltering and surge protection on the input

The other standards you will meet

  • EN 50155 onboard electronics
  • EN 45545-2 fire and smoke
  • EN 50121-3-2 EMC
  • EN 61373 shock and vibration
  • Passenger information and signage
  • Camera recording and surveillance
  • Data logging from the train bus
  • Diagnostics and predictive maintenance
  • Passenger Wi-Fi
  • Access and door control

A product from our range

Need computers for rail?

Tell us where the unit sits and which approvals you need.

Loading...